· The electrician company who installed it and changed the smoke detector does not know what to do. The constant beeping started 2 days ago after it was difficult to set the alarm. I did not get a manual with the system when it was installed in I wish I could have a manual or look at one on line. Perhaps I need a new security system. Thank you. MANUAL ISOLATION OF ALARM ZONES. There may be occasions when you need to isolate additional zones. Arm the system as above, then press * then the zone number you want to isolate. That zone will flash indicating a successful isolation, if you want more zones isolated press * and another zone. If any. Cable run (alarm sounder) 50m max with 7/ cable max with 16/ or 7/ paralleled Factory Defaults User/customer Code 1 User/customer Code 2 Disabled () Engineer Code Circuit 1 Entry Circuit. (Fixed) Circuit 2 Alarm Circuit isolated in Night set. Circuit 3 Alarm Circuit. Circuit 4 Alarm Circuit. Circuit 5 Alarm www.doorway.rug: intellisense.
I need to do a factory reset to my intellisense l alarm system as my wife has managed to change the code and - Answered by a verified Electronics Technician You will need the manual to setup the zones, delays etc as the reset will reset the whole panel and all the settings Neil, Technician. Category: Home Security Systems. 5 Detector reset (L+ when programmed for ID) Some detectors require the removal of power to reset (e.g. Viper Plus® or Smoke detectors). The L+ terminal can be programmed to be used as an 'ID' output using option The L+ terminal should then be used as the negative supply for these devices. Subsequent alarms are shown as f ast flashing lights. Zones that were isolated are shown as slow flashing lights. WHILE PANEL IS IN ALARM Go directly to the keypad and insert your user code, the system will disarm, the zone/s will light on the control panel to indicate the cause of the alarm, refer to panel reset to clear.(section).
Subsequent alarms are shown as fast flashing lights. Zones that were isolated are shown as slow flashing lights. WHILE PANEL IS IN ALARM Go directly to the keypad and insert your user code, the system will disarm, the zone/s will light on the control panel to indicate the cause of the alarm, refer to panel reset to clear.(section). REPLACES: • ADEMCO PR, , W • Aleph DC, DCWG • FBII ZR • GRI 29A • Intellisense MPS20 • Nascom NT • Sentrol T, T • Tane SM35 5. Surface Mount. Cable run (alarm sounder) 50m max with 7/ cable max with 16/ or 7/ paralleled Factory Defaults User/customer Code 1 User/customer Code 2 Disabled () Engineer Code Circuit 1 Entry Circuit. (Fixed) Circuit 2 Alarm Circuit isolated in Night set. Circuit 3 Alarm Circuit. Circuit 4 Alarm Circuit. Circuit 5 Alarm Circuit.
0コメント